Bahay > Mga Kaso ng Customer > Full-Chain Liquid Cooling sa mga Data Center: Ang Papel ng Cooling Distribution Unit (CDU), Cold Plates, Heat Sink, at Water Blocks

Full-Chain Liquid Cooling sa mga Data Center: Ang Papel ng Cooling Distribution Unit (CDU), Cold Plates, Heat Sink, at Water Blocks

2026-03-20 12:19:23

Sa panahon ng high-density computing, ang mga tradisyonal na air-cooling system ay mabilis na napapalitan ng mga advanced liquid cooling architecture. Sa kaibuturan ng transpormasyong ito ay nakasalalay ang data center cooling distribution unit (CDU)—isang kritikal na bahagi ng sistema na responsable para sa tumpak na paghahatid at regulasyon ng coolant sa buong imprastraktura ng server.

data center cooling distribution unit

kahulugan: ano ang isang data center cooling distribution unit (cdu)?

Ang cooling distribution unit (cdu) ay ang sentral na aparato ng distribusyon sa mga liquid-cooled data center, na naghahatid ng coolant—tubig man o fluorinated fluids—sa mga cold plate, immersion cooling tank, o direct-to-chip water block. Tinitiyak ng cdu ang naka-target na pag-alis ng init sa chip-level o rack-level, na nagpapahusay sa thermal efficiency at reliability sa mga modernong data center.


mga pangunahing tungkulin ng mga sistemang cdu

  1. distribusyon ng coolant: kinokontrol ang daloy gamit ang mga bomba at balbula upang matiyak ang balanseng paglamig para sa bawat server.

  2. Kontrol sa temperatura at presyon: pinapanatili ang temperatura ng coolant sa loob ng mahigpit na saklaw ng tolerance (±0.5°c) at tinitiyak ang matatag na presyon upang maiwasan ang cavitation o leakage.

  3. Disenyo ng redundancy: gumagamit ng dual-pump at dual-power na mga configuration upang matiyak ang 99.999% na availability.

  4. real-time na pagsubaybay: isinasama sa mga sistema ng dcim upang magbigay ng live na feedback sa mga rate ng daloy, temperatura, at katayuan ng tagas.

data center cooling distribution unit

mga uri ng mga yunit ng pamamahagi ng pagpapalamig ng data center

  • CDU sa antas ng rack: dinisenyo para sa iisang gamit sa kabinet, na sumusuporta sa kapasidad ng paglamig na 30-100kw. Mainam para sa mga scalable at flexible na pag-deploy.

  • row-level cdu: nagbibigay ng serbisyo sa isang buong hanay ng mga server rack na may suporta sa kuryente hanggang 500kw, mainam para sa mga high-density compute cluster.

  • Immersion CDU: partikular na ginawa para sa single-phase o two-phase immersion cooling systems, tugma sa mga fluorinated fluid tulad ng 3M Novec.

mga bentahe ng mga sistema ng paglamig ng likidong CDU

  • nakakamit ang bisa ng paggamit ng kuryente (pue) na kasingbaba ng 1.05, na nakakatipid ng 30%+ enerhiya kumpara sa pagpapalamig gamit ang hangin.

  • Sinusuportahan ang mga ultra-high-density na workload (hal., 50kw+ bawat rack para sa mga ai o gpu server).

  • tahimik na gumagana gamit ang mga disenyo ng cdu na walang fan (<50db noise level).


application scenarios

  • supercomputing facilities (e.g., japan's fugaku)

  • ai training clusters (e.g., nvidia dgx a100)

  • edge data centers with compact cdu footprints


cold plates, heat sinks, and water blocks: the execution layer of cdu cooling

while the cdu serves as the command center for liquid flow, its true cooling potential is realized through its terminal components: cdu water-cooled cold plates, heat sinks, and water blocks. these components directly interface with heat-generating devices to execute efficient thermal transfer.

componentcdu system roleapplication
cold platetransfers coolant to chips via microchannels for precise heat removalgpu/cpu-intensive racks, ai compute nodes
heat sinkprovides secondary cooling to cdu's internal electronicscdu control cabinet (pumps, psu modules)
water blockcustomized cooling of irregular thermal sources; connects with cdu pipeshpc systems, supercomputing accelerators

gpu cold plateuniversal cpu water block

technical advantages vs. traditional air cooling

1. cold plates (cdu water plates)

  • extreme heat flux capacity: supports up to 500–1000w/cm², outperforming air cooling (50–100w/cm²).

  • surface uniformity: delivers thermal spread with <2°c delta across the plate, preventing local overheating.

  • smart cdu integration: built-in sensors feed real-time data to cdu controllers, enabling dynamic flow and temperature regulation.

2. heat sinks for cdu internal components

  • cdu self-cooling: ensures cdu reliability by passively cooling key electronics.

  • lightweight design: aluminum 6063 construction minimizes weight, ideal for rack-mount cdu units.

3. custom water blocks (cdu water block solutions)

  • complex shape compatibility: cnc or 3d-printed to match non-standard chip designs (e.g., nvidia h100).

  • low flow resistance: engineered water channels reduce cdu pump workload (pressure drop < 0.3 bar).


cdu-component synergy: smart thermal management

modern cdu liquid cooling systems are not standalone—they function in harmony with cold plates, heat sinks, and water blocks to form a dynamic, closed-loop thermal architecture. key highlights include:

  • dynamic flow tuning: cdu adjusts coolant delivery based on feedback from water plates or water blocks (e.g., via intel dcm protocol).

  • leak protection: quick-disconnect fittings (e.g., cpc, qd) on water blocks and cdu hoses ensure sealed, safe connections.

  • energy efficiency: combined cdu + cold plate architecture can achieve pue as low as 1.05, compared to 1.5+ for traditional systems.


real-world applications

  • google data center: utilizes cdus to distribute chilled water to rack-mounted water plates for tpu cooling.

  • tesla dojo supercomputer: employs cdu-integrated custom water blocks to manage 1mw per cabinet.

  • crypto mining farms: use aluminum cold plates + cdu instead of fans, reducing power consumption by 30%.


future trends in cdu-based cooling solutions

  • two-phase cdu cooling: uses phase-change fluids like liquid nitrogen to achieve 5x efficiency gains.

  • ai-driven cdu control: enables predictive adjustments in flow and temperature based on workload forecasting.

as the backbone of next-generation data center infrastructure, the data center cooling distribution unit (cdu)—along with advanced cdu water plates, heat sinks, and liquid cooling water blocks—will continue to evolve toward smarter, quieter, and more efficient thermal management solutions.

keyword summary: data center cooling distribution unit (cdu), cdu water plate, cdu water block, immersion cdu, rack-level cdu, cold plate, heat sink, liquid cooling system, full-chain liquid cooling, water-cooled server, ai liquid cooling.


Kingka Tech Industrial Limited

Dalubhasa kami sa precision CNC machining at ang aming mga produkto ay malawakang ginagamit sa industriya ng telekomunikasyon, aerospace, automotive, pang-industriya na kontrol, power electronics, mga medikal na instrumento, security electronics, LED lighting at multimedia consumption.

Kontak

Address:

Da Long New Village, Xie Gang Town, Dongguan City, Guangdong Province, Tsina 523598


Email:

kenny@kingkametal.com


Tel:

+86 1371244 4018

Get A Quote
  • Mangyaring ipasok ang iyong name.
  • Mangyaring ipasok ang iyong E-mail.
  • Mangyaring ipasok ang iyong Telepono o WhatsApp.
  • Paki-refresh ang page na ito at ipasok muli
    Please fill in your requirements in detail so that we can provide a professional quotation.
  • Mag-upload ng File

    Pinapayagan ang mga extension ng file: .pdf, .doc, .docx, .xls, .zip

    Mag-drop ng mga file dito o

    Mga tinatanggap na uri ng file: pdf, doc, docx, xls, zip, Max. laki ng file: 40 MB, Max. mga file: 5.